Canty Home Page 

   Canty Process Lights
Sanitary Lighting
Industrial Lighting

   Fuseview ™ Sight Glasses
Sanitary Sight Glass & Sight Flows
Industrial Sight Glass & Sight Flows
 
   Particle Sizing
Have a need for particle sizing for the Lab and Online? Fill out our Particle Sizing Questionnaire and learn more about our particle sizing systems.
Oil & Gas
 
TRUFLOW™ PARTICLE SIZING SYSTEM
Document Number: TA11099-1
Detailed Datasheet
Further Information

The Canty TRUFLOW™ has been engineered to offer the user a means by which a liquid is analyzed while under varying pressures, temperatures and flow rates. It offers sample or continuous, microscopic, non-destructive viewing and provides particle size analysis with two dimensional results when used in conjunction with the CantyVisionClient™ Software.

PORTABLE INFLOW™ PORTABLE INFLOW™ Oil In Water Analyzer / Water In Oil Analyzer
Document Number: TA11317-1
Detailed Datasheet
Further Information

The PORTABLE INFLOW™ Oil In Water Analyzer / Water In Oil Analyzer combining the latest in Ethernet technology with Canty fused glass, lighting and CANTYVISIONCLIENT™ software, the INFLOW™ Process Particle Analyzer provides real time particle size and shape analysis. The Portable Multiphase Meter models measure 0.7 micron - 20,000 micron particles under process conditions. By continuously measuring the product OIL, WATER, SAND, and GAS the OiW / WiO is continually analyzed. This allows the user to see the impact of any change to the refining or drilling system. By using a vision based system CANTY can easily detect all phases and separate them to give PPM/PPB distribution as well as SIZE distribution of all particulates.

SURVEILLANCE CAMERAS SURVEILLANCE CAMERAS
Document Number: TA6898-1
Detailed Datasheet
Further Information

Canty Surveillance Cameras are ideal for demanding surveillance applications, visual inspection or verification functions in extreme environments.

Process Cameras Process Cameras
Document Number: TA7259-1
Detailed Datasheet
Further Information

J.M. Canty cameras are patented systems designed to illuminate and view inside a pressure or process vessel through a single connection. There is no need for multiple vessel ports. Canty supplies an integrally mounted camera and lighting system (optional) in a connection as small as a 2” NPT. The industry standard video output can be displayed on a video monitor in the comforts of a control room, or recorded on any VCR. A standard video monitor or TV with video input may be used to display the image.

ULTRA TEMPERATURE™ CAMERAS ULTRA TEMPERATURE™ CAMERAS
Document Number: TA7355-1
Detailed Datasheet
Further Information

Canty High Temperature Cameras are ideal for demanding applications involving visual inspection or verification in extreme temperature environments.

Explosion Proof PAN & TILT SYSTEM Explosion Proof PAN & TILT SYSTEM
Document Number: TA10844-1
Detailed Datasheet
Further Information

Canty pan & tilt systems have been designed for use in hazardous areas in accordance with explosion proof, and flame proof requirements.

TA11018-1 MicroFlow™ Oil In Water Analyzer / Water In Oil Analyzer
Document Number: TA11018-1
Detailed Datasheet
Further Information

The MicroFlow™ Oil In Water Analyzer / Water In Oil Analyzer offers sample or continuous, microscopic, non-destructive viewing and provides multiphase analysis of oil in water, water in oil with two dimensional results.

PHASE SPLIT PHASE SPLIT
Document Number: TA9788-1
Detailed Datasheet
Further Information

Monitor phase split in batch mode on organic droplets for increased product recovery. As the droplets appear the system warns of organic phase and the upcoming emulsion. The amount of early droplets and their retraction time will indicate the completeness of the separation. Once the split is identified and stopped, the operator has a visual verification from the video monitor. The color can then be analyzed to ensure there is no inversion.

IN-LINE TURBIDITY/COLOR ANALYSIS/PERCENTSOLIDS INFLOW™ TURBIDITY / COLOR ANALYSIS / PERCENT SOLIDS MEASUREMENT SYSTEMS
Document Number: TA10591-1
Detailed Datasheet
Further Information

The CANTY In-Line Turbidity, Color Measurement or Percent Solids Measurement System uses a 0-1” variable insertion measurement gap, which is unique to the Canty system. This insertion is made possible by the Fuseview™ sight glass, which allows the optical fused pieces to be located in the center of the fluid stream. This provides the highest velocity, most representative profile and automatically flushes the fused glass even in the harshest of environments.

TEMPERATURE MEASUREMENTS BY VISION TEMPERATURE MEASUREMENTS BY VISION
Document Number: TA10632-1
Detailed Datasheet
Further Information

Canty’s thermal vision system is quite similar to other radiative temperature methods, by measuring the energy produced by a process. The advancements in CCD cameras has allowed for the ability to measure wavelengths in both the visual range and near inferred range.

IN-FLOW OIL IN WATER / WATER IN OIL / MULTIPHASE OIL, WATER, TAR SANDS MEASUREMENT SYSTEM INFLOW™ OIL IN WATER ANALYZER / WATER IN OIL ANALYZER / MULTIPHASE OIL ANALYZER /PRODUCED WATER ANALYZER /TAR SANDS ANALYZER
Document Number: TA11014-1
Detailed Datasheet
Further Information

The INFLOW™ OIL IN WATER ANALYZER / WATER IN OIL ANALYZER / MULTIPHASE OIL ANALYZER /PRODUCED WATER ANALYZER /TAR SANDS ANALYZER combines the latest in CCD Ethernet camera technology with Canty fused glass, lighting and CANTYVISIONCLIENT™ software, the In-Flow Measurement System provides real time, in-line measurement of oil in water, water in oil, multiphase oil, water and tar sands.

FROTH CONTROL SYSTEM FROTH CONTROL SYSTEM
Document Number: TA10263-1
Detailed Datasheet
Further Information

An Ethernet camera is used to provide the measurement image to a customer supplied PC with Microsoft Windows based OS NT/XP/2000 and Ethernet connectivity. CantyVision™ software is included with each camera. CantyVision™ software interfaces with each camera thru TCP/IP to obtain digital images over an Ethernet network. The image from each camera is dynamically analyzed for bubble size, froth velocity and stability.

MIXED GAS FLAME MONITORING APPLICATION SHEET MIXED GAS FLAME MONITORING APPLICATION SHEET
Document Number: TA7616-1
Detailed Datasheet
Further Information

The Canty high temperature camera (option 2), or an Air cooled surveillance camera (option 1) is used to visually monitor the ladle. This image is then sent to the Canty Vector system to sense the flame presence in the zone, and the temperature of the refractory in several other zones.