ROUGING

Rouging in WFI (Water for Injection) systems refers to the formation of reddish-brown to dark violet iron deposits on the interior surfaces of stainless steel equipment, particularly in pharmaceutical and biotech industries. This phenomenon is a type of corrosion and is primarily caused by the oxidation of iron in the stainless steel, especially in the presence of hot WFI (above 60°C).  Rouge can detach from the surfaces and contaminate the WFI, potentially affecting the quality and safety of pharmaceutical products.  The CANTY InFlow™ detects these particles in real time, quantifying the amount of rouge being generated, providing an objective measure of system performance.

FEATURES

  • In-line real time concentration analysis
  • Count of suspended solids/rouge
  • Visual verification

1) INFLOW
2) SINGLE USE PARTICLE ANALYZER